Thermal Storage | Pure Thermal

Thermal Storage

The Pure Thermal Storage range delivers the next generation of Hot & Cold energy storage, providing load shifting and contingency benefits. These systems maximise the advantages of flexible electricity tariffs along with utilising low carbon electricity from either PV or grid.

Load shifting & Contingency delivering significant cost & carbon savings.

Contact The

Thermal Storage Experts




Thermal Energy Storage

Awareness is steadily developing within the UK of the increasing importance of energy storage, this usually relates to the storage of electricity BUT why not the storage of thermal energy?

Refrigeration, Cooling and Heating plant can produce cost effective thermal energy at any time if energy storage is available. What could be more straightforward than cost effectively storing Cold or Heat Energy within a compact battery to use when you need it?

  • REDUCE ENERGY COSTS

Pure Batteries enable the storage of Thermal Energy to maximise the use of low-cost input power/electricity from either Grid or on-site Solar PV to charge & accumulate cool or heat energy

  • REDUCE CARBON EMISSIONS

Pure Batteries enable carbon emissions to be reduced by operating condensers, chillers, or heat pumps with clean renewable input electricity from either Grid or PV when available

  • PROVIDE CONTINGENCY & SYSTEM RESILIENCE

Thermal Batteries provide contingency by delivering on demand stored thermal capacity should a failure occur with either the installed plant or the incoming site power supply

  • DEAL WITH HIGH AMBIENT TEMPERATURES

Utilise Cold Batteries to deal with unpredictable & variable peak load demands due to high ambient temperatures and provide stand-by refrigeration or cooling capacity

  • REDUCE INSTALLED PLANT CAPACITY

The capacity of installed plant can be minimised by utilising Thermal Batteries to provide peak ambient temperature kW capacity and deal with unpredictable climate variability

  • TURN OFF PLANT TO REMOVE OVERNIGHT NOISE

Pure Thermal Batteries enable noise related Planning Requirements to be easily achieved by operating the battery overnight and turning cooling plant off to remove noise problems

  • FLEXIBLE AND STRAIGHTFORWARD TO APPLY

Cold and Hot Battery systems can be utilised within chilled/cold storage facilities, process cooling/heating systems and HVAC applications

thermal storage

RETROFIT OR NEW INSTALLATION

thermal storage system

THE PURE PHASE CHANGE BATTERY RANGE

Pure Thermal provides three types of Thermal Battery systems:

PURE Compact UCS

Compact Uninterruptible Cooling or Heating Battery for both retrofit and new projects.

  • Temperature range -5 to 58C
  • Refrigeration, Cooling & Heating
  • Capacity range from 12kWh to 150kWh
  • Chill store integrated system
  • Programmable operation
  • Low tariff load shifting capability
  • Stand-alone contingent model with integral electricity supply battery
  • Programmable overnight zero noise option
  • Peak cooling demand management option

PURE Compact UCS

PURE Max TBS

High flow Thermal Battery System for both retrofit and new projects:

  • Temperature range -30 to 75C
  • Cooling & Heating/Hot Water
  • Capacity range from 35kWh to 1,500kWh
  • Programmable operation
  • Process and production system integration option
  • Low tariff load shifting capability
  • Stand-alone Contingency/Resilience option
  • Peak Cooling/Heating demand management option
  • Absorbs 4 x energy of equivalent water/glycol storage

PURE Modular CSB

High performance Cold Store Battery for both retrofit and new projects:

  • Temperature range -28C to 0C
  • Refrigeration & Cooling
  • Capacity range from 50kWh to 2,000kWh
  • Programmable operation
  • Peak refrigeration demand management
  • Low tariff load shifting capability
  • Contingency & resilience option
  • Absorbs 300 x more energy than frozen food

Retrofit or New Projects

Thermal Battery Operation

Thermal Energy is stored within Phase Change Material (PCM) packaged in modular or in-line formats which can accumulate and deliver considerable amounts of energy in comparison to sensible heat water or water/glycol tanks.

Pure Thermal Batteries are programmable, which means the stored energy can be utilised when required giving the user complete control of the available energy.

  • Thermal Energy is charged within the battery and delivered over a predetermined period dependent on the demands of the application
  • Operating range between -28ºC to 75ºC
  • Batteries can be charged via the existing plant or integrated within a packaged system with charging capability
  • Supplementary independent charging units can be specified to support existing installed systems where required

Thermal Battery Applications

  • Process and Production/Manufacturing
  • Pharmacy and Pharmaceutical Storage & Production
  • Commercial and Public Sector buildings
  • Hotels, Hospitality and Leisure
  • Retail and Logistics
  • District Heating & Cooling
  • Hospitals & Healthcare

Complete Support

Pure Thermal provides a complete service to the specifier, contractor or end user:

  • Load calculation and specification
  • Site survey with design input
  • Selection of application specific systems
  • Refrigeration system integration solutions
  • Installation support service
  • Commissioning service
  • Full manufacturer/factory support

THE COMPLETE APPLICATION SUPPORT SERVICE

Practical Innovation

  • Proven and established Thermal Storage Technology with a long history of operating within critical applications
  • PCM technology can be practically applied within a variety of applications to deliver energy cost savings and reductions in carbon emissions
  • The drive to increase efficiency along with a real focus on maximising value is now driving the application of Thermal Batteries forward.

Pure Efficency | Pure Sustainability | Pure savings